Show simple item record

dc.creatorKociubczyk, Alex Iván
dc.creatorMéndez, Claudia Marcela
dc.creatorGregorutti, Ricardo Walter
dc.creatorAres, Alicia Esther
dc.date.accessioned2023-01-30T12:37:00Z
dc.date.available2023-01-30T12:37:00Z
dc.date.issued2017-02-27
dc.identifier.citationKociubczyk, A. I., Méndez, C. M., Gregorutti, R. W., y Ares, A. E. (2017). Electrochemical analysis of the ASTM F75 alloy at different pH values and temperatures. Materials and Corrosion. Weinheim, Alemania : Wiley; 68(9), pp. 1-11.es_AR
dc.identifier.issn1521-4176
dc.identifier.otherCCPI-FCEQyN-A-124
dc.identifier.other8993
dc.identifier.urihttps://hdl.handle.net/20.500.12219/4437
dc.descriptionFil: Kociubczyk, Alex Iván. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico (Nordeste). Instituto de Materiales de Misiones; Argentina.es_AR
dc.descriptionFil: Kociubczyk, Alex Iván. Universidad Nacional de Misiones. Facultad de Ciencias Exactas, Químicas y Naturales. Instituto de Materiales de Misiones; Argentina.es_AR
dc.descriptionFil: Méndez, Claudia Marcela. Universidad Nacional de Misiones. Facultad de Ciencias Exactas, Químicas y Naturales; Argentina.es_AR
dc.descriptionFil: Gregorutti, Ricardo Walter. Comisión de Investigaciones científicas (Buenos Aires). Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina.es_AR
dc.descriptionFil: Ares, Alicia Esther. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico (Nordeste). Instituto de Materiales de Misiones; Argentina.es_AR
dc.descriptionFil: Ares, Alicia Esther. Universidad Nacional de Misiones. Facultad de Ciencias Exactas, Químicas y Naturales. Instituto de Materiales de Misiones; Argentina.es_AR
dc.description.abstractThe electrochemical behavior of ASTM F75 alloy was analyzed in a sodium chloride solution at pH values of 5, 7, and 9 and temperatures of 37 and 42 °C. The tests were performed in samples corresponding to two different regions of a hip prosthesis. Polarization curves showed that as pH increased the passivity range decreased. However, according to the complementary potentiodynamic–potentiostatic–potentiodynamic technique performed, the increase in the anodic current density was due to a change in the chromium oxidation state from Cr+3 to Cr+6 to form CrO4−2, and not to localized corrosion. On the other hand, neither the microstructure nor the temperature had influence on the electrochemical response of ASTM F75. The electrochemical impedance spectroscopy test showed that as pH increased, the passive film became more compact and thicker. However, its resistance decreased and the electrical double layer became more disordered, promoting diffusion processes of charged species. These results are in agreement with those obtained in the polarization curves, which showed an increase in the dissolution of the passive film, caused by the change in the chromium oxidation state, as pH increased.en
dc.formatapplication/pdf
dc.format.extent1.074 MB
dc.language.isoengen
dc.publisherWileyen
dc.relationinfo:eu-repo/semantics/altIdentifier/urn/https://onlinelibrary.wiley.com/doi/abs/10.1002/maco.201609394
dc.rightsCC0 1.0 Universal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/
dc.subjectAstm F75en
dc.subjectBiomaterialsen
dc.subjectCorrosionen
dc.subjectPhen
dc.subjectTemperatureen
dc.titleElectrochemical analysis of the ASTM F75 alloy at different pH values and temperaturesen
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC0 1.0 Universal
Except where otherwise noted, this item's license is described as CC0 1.0 Universal