Show simple item record

dc.creatorBenítez Mongelós, Pablo Daniel
dc.creatorRocha, Eugenio
dc.creatorRodrigues, Maria Fernanda
dc.date.accessioned2022-07-29T17:59:14Z
dc.date.available2022-07-29T17:59:14Z
dc.date.issued2021-02-08
dc.identifier.citationBenítez Mongelós,Pablo D., Rocha, E., y Rodrigues, M. F. (2021). Estrategias para la inspección óptima de estructuras de hormigón armado sujetas a corrosión. +Ingenio: Revista de Ciencia, Tecnología e Innovación. Oberá (Misiones): UNaM.FI; 2(2), pp. 46-58.es_AR
dc.identifier.issn2618-5520
dc.identifier.otherING-022
dc.identifier.uriinfo:eu-repo/semantics/altIdentifier/url/https://revistas.fio.unam.edu.ar/index.php/masingenio/article/view/201/541
dc.identifier.urihttps://hdl.handle.net/20.500.12219/3241
dc.descriptionFil: Benítez Mongelós, Pablo Daniel. Universidad Nacional de Itapúa. Facultad de Ingeniería; Paraguay.es_AR
dc.descriptionFil: Rocha, Eugenio. Universidad de Aveiro. Centro de Investigación y Desarrollo en Matemáticas y Aplicaciones; Portugal.es_AR
dc.descriptionFil: Rodrigues, Maria Fernanda. Universidad de Aveiro. Centro de Investigación de Riesgos y Sostenibilidad en la Construcción de Aveiro; Portugal.es_AR
dc.description.abstractGran parte de la estructura de hormigón armado se han construido en la primera mitad del Siglo XX,porloque su vida útil se encuentra actualmente en una etapa crítica desde la perspectiva del mantenimiento.Uno de los mecanismos de degradación más frecuentes y costosos en este tipo de infraestructura está asociado con la corrosión del refuerzo inducida por el fenómeno de carbonatación. Bajo este contexto,el objetivo de este artículo fue la formulación de un modelo de toma de decisiones para la planificación de la inspección óptima. Los tiempos de inspección fueron optimizados considerando la incertidumbre inherente al proceso de degradación y una compensación entre los costos de inspección y la capacidad de servicio de la estructura. Se ha elaborado un análisis de eficiencia través de dos enfoques: el Análisis de Frontera Estocástica y el Análisis de envolvente multidireccional. Este análisis proporciona una evaluación que reduce el número de técnicas de inspección necesarias y el intervalo de tiempo entre inspecciones para proporcionarnos una solución óptima, sino también más eficiente. Así, el resultado de esta investigación comprende un modelo numérico para la obtención de los tiempos de inspección más adecuados durante la vida útil de la estructura.es_AR
dc.description.abstractMuch of the reinforced concrete structures were built in the first half of the 20th century, so their service life is currently at a critical stage from a maintenance perspective. One of the mechanisms more frequent and costly degradation in this type of infrastructure is associated with reinforcement corrosion induced by the phenomenon of carbonation. In this context, the objective of this article was the formulation of a Decision-making model for optimal inspection planning. The inspection times were optimized considering the uncertainty inherent in the degradation process and a trade-off between the costs of inspection and serviceability of the structure. An efficiency analysis has been developed through two approaches: Stochastic Frontier Analysis and Multidirectional Envelope Analysis. This analysis provides an assessment that reduces the number of inspection techniques required and the time interval between inspections to provide not only an optimal solution, but also a more efficient one. Thus, the result of this research It comprises a numerical model to obtain the most adequate inspection times during the useful life of the structure.en
dc.formatapplication/pdf
dc.format.extent820 MB
dc.language.isospaes_AR
dc.publisherUniversidad Nacional de Misiones. Facultad de Ingeniería. Secretaría de Ciencia y Técnicaes_AR
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.36995/j.masingenio.2021.02.02.004
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRevista + Ingenio (Misiones), 2-2021; 2(2): pp. 46-58 https://revistas.fio.unam.edu.ar/index.php/masingenio/index
dc.subjectAnálisis de eficienciaes_AR
dc.subjectCarbonataciónes_AR
dc.subjectCorrosiónes_AR
dc.subjectDurabilidades_AR
dc.subjectHormigón armadoes_AR
dc.subjectInspecciónes_AR
dc.subjectMantenimientoes_AR
dc.subjectModelo de decisiónes_AR
dc.subjectOptimizaciónes_AR
dc.subjectEfficiency analysisen
dc.subjectCarbonationen
dc.subjectCorrosionen
dc.subjectDurabilityen
dc.subjectConcrete Reinforceden
dc.subjectInspectionen
dc.subjectMaintenanceen
dc.subjectDecision modelen
dc.subjectOptimizationen
dc.titleEstrategias para la inspección óptima de estructuras de hormigón armado sujetas a corrosiónes_AR
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • Revista +INGENIO [53]
    La Revista de Ciencia, Tecnología e Innovación de la Facultad de Ingeniería de la Universidad Nacional de Misiones, es una publicación de periodicidad semestral y los artículos se reciben durante todo el año. El objetivo de la revista es proporcionar un espacio de difusión y discusión sobre los aspectos científicos, tecnológicos y de innovación en las ingenierías. La publicación está dirigida al público en general interesado en la investigación, el desarrollo tecnológico, la innovación y la transferencia, promoviendo un espacio para fomentar la discusión e interacción entre los miembros de la comunidad.

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess