Show simple item record

Experimental electronic system for the measurement of gait parameter variables in elderly people

dc.rights.licenseLicencia de Creative Commons Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)
dc.creatorMenéndez Álvarez, Jaime
dc.creatorArencibia Castellanos, Gianna
dc.creatorHernández Montero, Fidel Ernesto
dc.creatorRodríguez Suárez, Juan Raúl
dc.creatorPérez Molinet, Ailén
dc.date.accessioned2020-09-29T22:41:32Z
dc.date.available2020-09-29T22:41:32Z
dc.date.issued2020-06-25
dc.identifier.citationMenéndez Álvarez, J., Arencibia Castellanos, G., Hernández Montero, F. E., Rodríguez Suárez, J. R., y Pérez Molinet, A. (2020). Sistema electrónico experimental para la medición de variables de parámetros de marcha en ancianos. Revista de Ciencia y Tecnología (RECyT). Posadas (Misiones): UNaM. FCEQyN; 33(1), 108-115.es_AR
dc.identifier.issn1851-7587
dc.identifier.otherRCyT-029
dc.identifier.urihttps://hdl.handle.net/20.500.12219/2609
dc.identifier.urihttps://doi.org/10.36995/j.recyt.2020.33.014
dc.identifier.urihttps://www.fceqyn.unam.edu.ar/recyt/index.php/recyt/article/view/582
dc.descriptionFil: Menéndez Álvarez, Jaime. Universidad Tecnológica de La Habana "José Antonio Echeverría". Facultad de Telecomunicaciones y Electrónica; Cuba.es_AR
dc.descriptionFil: Arencibia Castellanos, Gianna. Universidad Tecnológica de La Habana "José Antonio Echeverría". Facultad de Telecomunicaciones y Electrónica; Cuba.es_AR
dc.descriptionFil: Hernández Montero, Fidel Ernesto. Universidad Tecnológica de La Habana "José Antonio Echeverría". Facultad de Telecomunicaciones y Electrónica; Cuba.es_AR
dc.descriptionFil: Rodríguez Suárez, Juan R. Universidad Tecnológica de La Habana "José Antonio Echeverría". Facultad de Telecomunicaciones y Electrónica; Cuba.es_AR
dc.descriptionFil: Ailén, Pérez Molinet. Universidad Tecnológica de La Habana "José Antonio Echeverría". Facultad de Telecomunicaciones y Electrónica; Cuba.es_AR
dc.description.abstractEn el estudio actual que se realiza en Cuba sobre el monitoreo de indicadores del desempeño físico en ancianos, los parámetros medidos son afectados por la subjetividad del especialista que realiza las mediciones y no se tiene en cuenta la variabilidad que puede existir en estos. Desarrollar y evaluar en un entorno de laboratorio un sistema electrónico, de bajo costo, capaz de medir de forma inalámbrica estas variables físicas brinda la posibilidad de obtener parámetros de la marcha de manera automática. El sistema diseñado está basado en una Unidad de Medición Inercial (IMU) por tanto es capaz de medir la aceleración lineal y la velocidad angular en los tres ejes coordenados, así como la temperatura. El sistema transmite los datos de forma inalámbrica vía Bluetooth hacia una PC donde se implementa la etapa de procesamiento. Se evalúa el sistema de medición diseñado con diferentes pruebas que demuestran un comportamiento satisfactorio. También se muestran los resultados obtenidos al usar el dispositivo, en una prueba de equilibrio dinámico; en la cual las variables físicas obtenidas del IMU son procesadas con el fin de obtener el ángulo de inclinación del sensor.es_AR
dc.description.abstractThis research, which is carried out in Cuba, is about the monitoring of physical performance indicators on elderly people. The parameters under measurement are affected by the specialist subjectivity who measures the parameters without carefully considering the variability that may exist among them. Developing and evaluating, within a laboratory environment, a low-cost electronic system capable of wirelessly measuring these physical variables, allows the possibility to automatically obtain gear parameters. This system is based on an Inertial Measurement Unit (IMU) that is able to measure not only the linear acceleration and angular speed in the three coordinate axes but also the temperature. At the same time, the system transmits data, via Bluetooth, to a PC where signal processing techniques are implemented. The designed measurement system is evaluated through different proofs which demonstrate a satisfying behavior. The obtained results are also shown when using this system in a dynamic equilibrium test in which the physical variables obtained by the IMU are processed to get the sensor angle inclination.en
dc.formatapplication/pdf
dc.language.isospaes_AR
dc.publisherUniversidad Nacional de Misiones. Facultad de Ciencias Exactas, Químicas y Naturales. Secretaria de Investigación y Posgradoes_AR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRevista de Ciencia y Tecnología (Misiones), 6-2020; 33(1): pp. 108-115 https://www.fceqyn.unam.edu.ar/recyt/index.php/recyt
dc.subjectIMUes_AR
dc.subjectSistema de Adquisiciónes_AR
dc.subjectArduinoes_AR
dc.subjectIndicadores de desempeño físicoes_AR
dc.subjectAcquisition Systemen
dc.subjectArduinoen
dc.subjectPhysical performance indicatorsen
dc.titleSistema electrónico experimental para la medición de variables de parámetros de marcha en ancianoses_AR
dc.titleExperimental electronic system for the measurement of gait parameter variables in elderly peopleen
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • Revista de Ciencia y Tecnología (RECyT) [55]
    La Revista de Ciencia y Tecnología (RECyT) publica artículos originales que representan una contribución para el desarrollo científico-tecnológico. Colección correspondiente a las áreas de incumbencia: Biología - Genética - Bioquímica - Farmacia

Show simple item record

Licencia de Creative Commons Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)
Except where otherwise noted, this item's license is described as Licencia de Creative Commons Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)